top of page
Advanced Liquid Transmission Cells

Advanced Liquid Transmission Cells

Features

  • Rugged stainless steel construction
  • Choice of window materials
  • Sealed and demountable cell options
  • Static and flow cell options
  • Can be used for heated and cooled sample analysis
  • More details

    Range of liquid FTIR transmission cells

    Specac offers a range of Advanced Liquid Transmission Cells in sealed, demountable, static, and flow configurations to allow liquid samples to be studied at temperatures other than ambient.

    A choice of window materials allows for spectral analysis in the UV, Visible, NIR, and IR.

    Controlled temperature FTIR cells

    These cells are intended for use with Specac’s transmission cell holders to achieve the required temperature conditions, namely:

    • Electrical Heating Jacket
    • Variable Temperature Cell Holder
    • Water Heating Jacket
    • Ambient Cell Holder

    Rugged FTIR liquid cells

    All Specac Advanced Liquid Transmission Cells are rugged stainless steel constructions for ongoing reliability, and include a thermocouple well for in-situ temperature monitoring.

  • LIST OF CELLS

    STATIC CELLS

    • Sealed Static Cell – NaCl windowsSealed, Heatable Liquid Cell Complete with NaCl windows and lead spacer (specify pathlength from 0.025, 0.05, 0.1, 0.2, 0.5 and 1.0mm).GS20500

    • Sealed Static Cell – KBr windowsSealed, Heatable Liquid Cell Complete with KBr windows and lead spacer (specify pathlength from 0.025, 0.05, 0.1, 0.2, 0.5 and 1.0mm).GS20501

    • Sealed Liquid Cell – CaF2 windowsSealed, Heatable Liquid Cell Complete with CaF2 windows and lead spacer (specify pathlength from 0.025, 0.05, 0.1, 0.2, 0.5 and 1.0mm).GS20502

    • Sealed Static Cell – BaF2 windowsSealed, Heatable Liquid Cell Complete with BaF2 windows and lead spacer (specify pathlength from 0.025, 0.05, 0.1, 0.2, 0.5 and 1.0mm).GS20503

    • Sealed Static Cell – ZnSe windowsSealed, Heatable Liquid Cell Complete with ZnSe windows and lead spacer (specify pathlength from 0.025, 0.05, 0.1, 0.2, 0.5 and 1.0mm).GS20508

    • Demountable Static Cell – NaCl windowsDemountable, Heatable Liquid Cell Complete with NaCl windows and Mylar or PTFE spacer (specify pathlength from 0.006, 0.012, 0.025, 0.05, 0.1, 0.2, 0.5 and 1.0mm).GS20510

    • Demountable Static Cell – KBr windowsDemountable, Heatable Liquid Cell Complete with KBr windows and Mylar or PTFE spacer (specify pathlength from 0.006, 0.012, 0.025, 0.05, 0.1, 0.2, 0.5 and 1.0mm).GS20511

    • Demountable Static Cell – CaF2 windowsDemountable, Heatable Liquid Cell Complete with CaF2 windows and Mylar or PTFE spacer (specify pathlength from 0.006, 0.012, 0.025, 0.05, 0.1, 0.2, 0.5 and 1.0mm).GS20512

    • Demountable Static Cell – BaF2 windowsDemountable, Heatable Liquid Cell Complete with BaF2 windows and Mylar or PTFE spacer (specify pathlength from 0.006, 0.012, 0.025, 0.05, 0.1, 0.2, 0.5 and 1.0mm).GS20513

    • Demountable Static Cell – ZnSe windowsDemountable, Heatable Liquid Cell Complete with ZnSe windows and Mylar or PTFE spacer (specify pathlength from 0.006, 0.012, 0.025, 0.05, 0.1, 0.2, 0.5 and 1.0mm).GS20519

    VARIABLE TEMPERATURE FLOW CELLS (VT)

    • VT Sealed Flow Cell – NaCl windowsSealed, Heatable Liquid Flow Cell Complete with NaCl windows and lead spacer (1/16" O.D. Tubing and Swagelok Connections) - (specify pathlength from 0.025, 0.05, 0.1, 0.2, 0.5 and 1.0mm).GS20560

    • VT Sealed Flow Cell – KBr windowsSealed, Heatable Liquid Flow Cell Complete with KBr windows and lead spacer (1/16" O.D. Tubing and Swagelok Connections) - (specify pathlength from 0.025, 0.05, 0.1, 0.2, 0.5 and 1.0mm).GS20561

    • VT Sealed Flow Cell – CaF2 windowsSealed, Heatable Liquid Flow Cell Complete with CaF2 windows and lead spacer (1/16" O.D. Tubing and Swagelok Connections) - (specify pathlength from 0.025, 0.05, 0.1, 0.2, 0.5 and 1.0mm).GS20562

    • VT Sealed Flow Cell – BaF2 windowsSealed, Heatable Liquid Flow Cell Complete with BaF2 windows and lead spacer (1/16" O.D. Tubing and Swagelok Connections) - (specify pathlength from 0.025, 0.05, 0.1, 0.2, 0.5 and 1.0mm).GS20563

    • VT Sealed Flow Cell – ZnSe windowsSealed, Heatable Liquid Flow Cell Complete with ZnSe windows and lead spacer (1/16" O.D. Tubing and Swagelok Connections) - (specify pathlength from 0.025, 0.05, 0.1, 0.2, 0.5 and 1.0mm).GS20566

    • VT Sealed Flow Cell – Spec B windowsSealed, Heatable Liquid Flow Cell Complete with Spec B (UV quartz) windows and lead spacer (1/16" O.D. Tubing and Swagelok Connections) - (specify pathlength from 0.025, 0.05, 0.1, 0.2, 0.5 and 1.0mm)GS20567

    • VT Demountable Flow Cell – NaCl windowsDemountable, Heatable Liquid Flow Cell Complete with NaCl windows and Mylar or PTFE spacer (1/16" O.D. Tubing and Swagelok Connections) - (specify pathlength from 0.006, 0.012, 0.025, 0.05, 0.1, 0.2, 0.5 and 1.0mm).GS20590

    • VT Demountable Flow Cell – KBr windowsDemountable, Heatable Liquid Flow Cell Complete with KBr windows and Mylar or PTFE spacer (1/16" O.D. Tubing and Swagelok Connections) - (specify pathlength from 0.006, 0.012, 0.025, 0.05, 0.1, 0.2, 0.5 and 1.0mm)GS20591

    • VT Demountable Flow Cell – CaF2 windowsDemountable, Heatable Liquid Flow Cell Complete with CaF2 windows and Mylar or PTFE spacer (1/16" O.D. Tubing and Swagelok Connections) - (specify pathlength from 0.006, 0.012, 0.025, 0.05, 0.1, 0.2, 0.5 and 1.0mm).GS20592

    • VT Demountable Flow Cell – BaF2 windowsDemountable, Heatable Liquid Flow Cell Complete with BaF2 windows and Mylar or PTFE spacer (1/16" O.D. Tubing and Swagelok Connections) - (specify pathlength from 0.006, 0.012, 0.025, 0.05, 0.1, 0.2, 0.5 and 1.0mm).GS20593

    • VT Demountable Flow Cell – ZnSe windowsDemountable, Heatable Liquid Flow Cell Complete with ZnSe windows and Mylar or PTFE spacer (1/16" O.D. Tubing and Swagelok Connections) - (specify pathlength from 0.006, 0.012, 0.025, 0.05, 0.1, 0.2, 0.5 and 1.0mm).GS20594

bottom of page